当前位置:CRM > 科技问答 > 曾招维,某局点交换机堆叠线断开测试后,再堆叠时备机不停重启

曾招维,某局点交换机堆叠线断开测试后,再堆叠时备机不停重启

2023-06-05 14:12:07科技问答
1685945527,

组网及说明

现场开局,客户反馈两台设备正常堆叠起来之后,做断开堆叠线测试,然后再接上堆叠线,发现slot2设备不断重启。

问题描述

display hardware-resource查看两个设备的硬件资源一致,堆叠配置没有异常,irf-port-configuration active重新激活IRF断开配置故障依旧。

Slot1在堆叠备设备重启过程中无异常信息:

<JXGCLXY-1F-C-09_C-08-ASW-H6900-01U47>%Jan  4 13:00:27:859 2011 JXGCLXY-1F-C-09_C-08-ASW-H6900-01U47 IFNET/3/PHY_UPDOWN: Physical state on the interface FortyGigE1/0/53 changed to up.

%Jan  4 13:00:27:860 2011 JXGCLXY-1F-C-09_C-08-ASW-H6900-01U47 IFNET/5/LINK_UPDOWN: Line protocol state on the interface FortyGigE1/0/53 changed to up.

%Jan  4 13:00:28:675 2011 JXGCLXY-1F-C-09_C-08-ASW-H6900-01U47 STM/6/STM_LINK_UP: IRF port 2 came up.

%Jan  4 13:00:29:021 2011 JXGCLXY-1F-C-09_C-08-ASW-H6900-01U47 STM/4/STM_MERGE: IRF merge occurred.

%Jan  4 13:00:29:269 2011 JXGCLXY-1F-C-09_C-08-ASW-H6900-01U47 LAGG/6/LAGG_INACTIVE_PHYSTATE: Member port XGE1/0/47 of aggregation group BAGG1023 changed to the inactive state, because the physical state of the port is down.  ///////这个是BFD检测端口

%Jan  4 13:00:29:270 2011 JXGCLXY-1F-C-09_C-08-ASW-H6900-01U47 IFNET/3/PHY_UPDOWN: Physical state on the interface Ten-GigabitEthernet1/0/47 changed to down.

%Jan  4 13:00:29:271 2011 JXGCLXY-1F-C-09_C-08-ASW-H6900-01U47 IFNET/5/LINK_UPDOWN: Line protocol state on the interface Ten-GigabitEthernet1/0/47 changed to down.

%Jan  4 13:00:29:279 2011 JXGCLXY-1F-C-09_C-08-ASW-H6900-01U47 STM/3/STM_LINK_DOWN: IRF port 2 went down.

过程分析

再次核对两个设备配置,发现部分配置不一致,按理来讲堆叠成功后备机会同步主机配置,分裂后两个设备配置应该一致。

设备A:

#

irf mac-address persistent timer

irf auto-update enable

irf link-delay 0

irf member 1 priority 30

#

#

interface Bridge-Aggregation13

description dT:cunchu:JXGCLXY-1F-C-09-SEV-ZXR5300G4X-02U17.Bond0

port access vlan 2110

link-aggregation mode dynamic

stp edged-port

stp port bpdu-protection enable

#

设备B

#

irf mac-address persistent timer

irf auto-update enable

undo irf link-delay

irf member 2 priority 20

#

#

interface Bridge-Aggregation13

description dT:cunchu:JXGCLXY-1F-C-09-SEV-ZXR5300G4X-02U17.Bond0

port link-type trunk

undo port trunk permit vlan 1

port trunk permit vlan 2110

link-aggregation mode dynamic

stp edged-port

stp port bpdu-protection enable

#

解决方法

将两端配置修改成一致后,正常堆叠成功。

后经确认客户第一次堆叠起来之后修改了irf link-delay配置,但没有保存配置就断开堆叠线,造成备机配置与主机不一致。