SecPath F1060 配置context分配接口报错
问题描述:
两台F1060做了IRF2,之后配置Context。在给Context分配接口时,可以选择独占方式分配(不带share参数)、共享方式分配(带share参数),但是选择独占方式时,分配端口会报错:Group error: all interfaces of one group must be allocated to the same mdc.与手册描述不符,请问是什么原因?
(4)
最佳答案
已采纳 悠哈悠哈 悠哈悠哈 六段 粉丝:0人 关注:0人
确认是在防火墙配置的?防火墙是context命令,不是mdc。
[F5020]mdc 1
^
% Unrecognized command found at '^' position.
[F5020]context 1
[F5020-context-5-1]allocate interface GigabitEthernet 1/0/?
<0-22> GigabitEthernet interface number
[F5020-context-5-1]allocate interface GigabitEthernet 1/0/22
Configuration of the interfaces will be lost. Continue? [Y/N]:y
GigabitEthernet1/0/22 has been allocated in sharing mode. Please cancel the allocation in sharing mode first.
[F5020-context-5-1]allocate interface g1/0/22 share
[F5020-context-5-1]
[F5020-context-5-1]allocate interface GigabitEthernet 1/0/19
Configuration of the interfaces will be lost. Continue? [Y/N]:y
[F5020-context-5-1]
(4)
回复xxx [x] 2
· 对于本系列交换机,一块业务板上的所有接口只能加入一个MDC。因此为某个MDC分配接口时,请将一块业务板上的所有接口分配给该MDC。
# 将接口FortyGigE1/0/1分配给MDC sub1。
<Sysname> system-view
[Sysname] mdc sub1
[Sysname-mdc-2-sub1] allocate interface fortygige 1/0/1
Configuration of the interfaces will be lost. Continue? [Y/N]:y
Group error: all interfaces of one group must be allocated to the same mdc.
FortyGigE1/0/1
Port list of group 4:
FortyGigE1/0/1 FortyGigE1/0/2
FortyGigE1/0/3 FortyGigE1/0/4
FortyGigE1/0/5 FortyGigE1/0/6
FortyGigE1/0/7 FortyGigE1/0/8
以上提示信息表明必须将接口FortyGigE1/0/1~FortyGigE1/0/8一起分配给同一个MDC。执行如下命令,将接口FortyGigE1/0/1~FortyGigE1/0/8一起分配给MDC sub1:
[Sysname-mdc-2-sub1] allocate interface fortygige 1/0/1 to fortygige 1/0/8
Configuration of the interfaces will be lost. Continue? [Y/N]:y
所以应该是出于系统硬件或者版本的限制导致,建议更换设备测试一下!
(1)
回复xxx [x] 已采纳 知了知了 知了知了 九段 粉丝:98人 关注:0人华三官网的资料都是经过物理设备,真机验证过后得到的结果,一般不会出现测试结果不一致的问题。建议注意核对设备版本和配置方法的差异。
(1)
[H3C-context-10-con10]allocate interface GigabitEthernet 1/0/11 Configuration of the interfaces will be lost. Continue? [Y/N]:y Group error: all interfaces of one group must be allocated to the same mdc. GigabitEthernet1/0/11 Port list of group 1: GigabitEthernet1/0/0 GigabitEthernet1/0/1 GigabitEthernet1/0/2 GigabitEthernet1/0/3 GigabitEthernet1/0/4 GigabitEthernet1/0/5 GigabitEthernet1/0/6 GigabitEthernet1/0/7 GigabitEthernet1/0/8 GigabitEthernet1/0/9 GigabitEthernet1/0/10 GigabitEthernet1/0/11