交换机接光纤后不能上网
问题描述:
原型号S51
现在新交换机S5024PV2-EI按照之前S51
麻烦各位看下我按照S51
组网及组网描述:
麻烦各位大神看下我根据之前交换机的配置内容,在新型号交换机配置内容中更新的对不对
附件下载: 原型号S515小时前提问
看一下光功率
5小时前回答 (10)<H3C>display transceiver diagnosis interface GigabitEthernet1/0/25 transceiver diagnostic information: Current diagnostic parameters: Temp.(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm) 48 3.47 25.88 -7.51 -5.84 GigabitEthernet1/0/26 transceiver diagnostic information: Error: The transceiver is absent. GigabitEthernet1/0/27 transceiver diagnostic information: Error: The transceiver is absent. GigabitEthernet1/0/28 transceiver diagnostic information: Current diagnostic parameters: Temp.(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm) 48 3.45 22.70 -40.00 -3.88 <H3C>
军4个光口,只有25和28是插了光模块 ,目前光纤是接在25口上
军放到下面吧,合一起看不清
z6Kl9<H3C>display transceiver diagnosis interface GigabitEthernet1/0/25 transceiver diagnostic information: Current diagnostic parameters: Temp.(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm) 48 3.47 25.88 -7.51 -5.84
军GigabitEthernet1/0/26 transceiver diagnostic information: Error: The transceiver is absent.
军GigabitEthernet1/0/27 transceiver diagnostic information: Error: The transceiver is absent.
军GigabitEthernet1/0/28 transceiver diagnostic information: Current diagnostic parameters: Temp.(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm) 48 3.45 22.70 -40.00 -3.88
军我的意思是放到新的里
z6Kl9好的
军已截图放到新里面
军看看对端的收发光功率和配置
z6Kl9稍等一下
军已发
军原来是25口对25口吗
z6Kl9是的,对应的
军25和28都一样的效果,试过
军版本升级到之前设备一样的试试看
z6Kl9刚在对端上传了28对28的图片
军升级包在哪可以下载呢?
军https://www.h3c.com/cn/d_
好的,谢谢
军可以登录,再麻烦问下,从S5024PV2-EI 能直接升级到S51
交换机型号不一样,只能换
z6Kl9你正在内容来源:知了社区,交换机接光纤后不能上网