首页 科技问答 L5000 双链路,链路1链路探测失败 日志分析,接口没down,几秒钟自动恢复,设备自身有问题吗

L5000 双链路,链路1链路探测失败 日志分析,接口没down,几秒钟自动恢复,设备自身有问题吗

科技问答 129
1688656450,CRM论坛(CRMbbs.com)——一个让用户更懂CRM的垂直性行业内容平台,CRM论坛致力于互联网、客户管理、销售管理、SCRM私域流量内容输出5年。 如果您有好的内容,欢迎向我们投稿,共建CRM多元化生态体系,创建CRM客户管理一体化生态解决方案。内容来源:知了社区

问题描述:

L5000 双链路,链路1链路探测失败 日志分析,接口没down,几秒钟自动恢复,设备自身有问题吗

设备日志如下:

L5000 BFD/5/BFD_CHANGE_FSM: Sess*****, LD/RD:130/130, Interface:Reth1, SessType:Echo, LinkType:INET], Ver:1, Sta: UP->DOWN, Diag: 2 (Echo Function Failed)

L5000 BFD/5/BFD_CHANGE_FSM: Sess[**********, LD/RD:130/130, Interface:Reth1, SessType:Echo, LinkType:INET], Ver:1, Sta: DOWN->INIT, Diag: 0 (No Diagnostic)

 L5000 BFD/5/BFD_CHANGE_FSM: Sess[**************, LD/RD:130/130, Interface:Reth1, SessType:Echo, LinkType:INET], Ver:1, Sta: INIT->DOWN, Diag: 1 (Control Detection Time Expired)

 L5000 BFD/5/BFD_CHANGE_FSM: Sess[*************, LD/RD:130/130, Interface:Reth1, SessType:Echo, LinkType:INET], Ver:1, Sta: DOWN->INIT, Diag: 0 (No Diagnostic)

L5000 BFD/5/BFD_CHANGE_FSM: Sess[***********, LD/RD:130/130, Interface:Reth1, SessType:Echo, LinkType:INET], Ver:1, Sta: INIT->UP, Diag: 0 (No Diagnostic)

L5000 BFD/5/BFD_CHANGE_FSM: Sess[************, LD/RD:130/130, Interface:Reth1, SessType:Echo, LinkType:INET], Ver:1, Sta: UP->DOWN, Diag: 2 (Echo Function Failed)

L5000 NQA/6/NQA_ENTRY_PROBE_RESULT: Reaction entry 1 of NQA entry admin-name admin operation-tag test: probe-fail.

L5000 BFD/5/BFD_CHANGE_FSM: Sess[*************************, LD/RD:130/130, Interface:Reth1, SessType:Echo, LinkType:INET], Ver:1, Sta: DOWN->INIT, Diag: 0 (No Diagnostic)

 L5000 BFD/5/BFD_CHANGE_FSM: Sess[*************************, LD/RD:130/130, Interface:Reth1, SessType:Echo, LinkType:INET], Ver:1, Sta: INIT->UP, Diag: 0 (No Diagnostic) L5000 BFD/5/BFD_CHANGE_FSM: Sess[*************************, LD/RD:130/130, Interface:Reth1, SessType:Echo, LinkType:INET], Ver:1, Sta: UP->DOWN, Diag: 2 (Echo Function Failed) 

L5000 BFD/5/BFD_CHANGE_FSM: Sess[*************************, LD/RD:130/130, Interface:Reth1, SessType:Echo, LinkType:INET], Ver:1, Sta: DOWN->INIT, Diag: 0 (No Diagnostic) 

L5000 BFD/5/BFD_CHANGE_FSM: Sess[*************************, LD/RD:130/130, Interface:Reth1, SessType:Echo, LinkType:INET], Ver:1, Sta: INIT->UP, Diag: 0 (No Diagnostic) 

L5000 BFD/5/BFD_CHANGE_FSM: Sess[*************************, LD/RD:130/130, Interface:Reth1, SessType:Echo, LinkType:INET], Ver:1, Sta: UP->DOWN, Diag: 2 (Echo Function Failed) 

L5000 BFD/5/BFD_CHANGE_FSM: Sess[*************************, LD/RD:130/130, Interface:Reth1, SessType:Echo, LinkType:INET], Ver:1, Sta: DOWN->INIT, Diag: 0 (No Diagnostic) 

L5000 BFD/5/BFD_CHANGE_FSM: Sess[*************************, LD/RD:130/130, Interface:Reth1, SessType:Echo, LinkType:INET], Ver:1, Sta: INIT->UP, Diag: 0 (No Diagnostic) 

L5000 NQA/6/NQA_ENTRY_PROBE_RESULT: Reaction entry 1 of NQA entry admin-name admin operation-tag test: probe-pass. 

 L5000 LB/5/LB_CHANGE_LINK_PROBERESULT: The probe state of link lianlu1 template lb1 was changed to Failed. 

 L5000 LB/5/LB_CHANGE_LINK_HCSTATUS: The health state of link lianlu1 was changed to Inactive. Last state was kept for 188933 seconds. L5000 LB/5/LB_CHANGE_LINK_PROBERESULT: The probe state of link lianlu1 template lb1 was changed to Succeeded. 

 L5000 LB/5/LB_CHANGE_LINK_HCSTATUS: The health state of link lianlu1 was changed to Active. Last state was kept for 27 seconds. 

L5000 LB/5/LB_LINK_STATE_ACTIVE: The state of link lianlu1 is active.

组网及组网描述:


7小时前提问

您好,可以升级版本再进行观察

7小时前回答

暂无

链路探测建议使用NQA来探测


7小时前回答

暂无

你正在,L5000 双链路,链路1链路探测失败 日志分析,接口没down,几秒钟自动恢复,设备自身有问题吗

BFD