首页 科技问答 孔凡安,SecPath M9000-X异常日志“Hardware failures have occurred on multiple cards. Please contact Technical Support.”

孔凡安,SecPath M9000-X异常日志“Hardware failures have occurred on multiple cards. Please contact Technical Support.”

科技问答 378
1685945533,

问题描述

新到货设备SecPath M9000-X异常日志“Hardware failures have occurred on multiple cards. Please contact Technical Support.”

解决方法

现场使用的是国产化主控搭配留待板卡。

国产主控使用E9571Pxx版本,业务板使用E9671Pxx。

  ===============display device verbose=============== 

Slot No. Brd Type         Brd Status   Subslot Sft Ver                Patch Ver

0       NSQM7MBSHA0      Normal       0       M9000-X06-9571P19      None     

         NS-FWFFGB0(CPU1) Normal       1       M9000-X06-9571P19     ---FWF对应六代板卡

         NS-C300-TG24A1                2       NONE                  

 1       NSQM7MBSHA0      Normal       0       M9000-X06-9571P19      None     

         NS-FWFFGB0(CPU1) Normal       1       M9000-X06-9571P19     

         NS-C300-TG24A1                2       NONE                  

 2       NONE             Absent       0       NONE                   None     

 3       NONE             Absent       0       NONE                   None     

 4       NSQM7SUPB0-CN    Master       0       M9000-X06-9571P19      None     

 5       NSQM7SUPB0-CN    Standby      0       M9000-X06-9571P19      None      ---CN对应国产化

 6       NSQM7FAB06A0     Normal       0       NONE                   None     

 7       NSQM7FAB06A0     Normal       0       NONE                   None     

 8       NSQM7FAB06A0     Normal       0       NONE                   None     

 9       NSQM7FAB06A0     Normal       0       NONE                   None  

内容来源:知了社区,基于知识共享署名-相同方式共享3.0中国大陆许可协议
CRM论坛(CRMbbs.com)——一个让用户更懂CRM的垂直性行业内容平台,CRM论坛致力于互联网、客户管理、销售管理、SCRM私域流量内容输出5年。 如果您有好的内容,欢迎向我们投稿,共建CRM多元化生态体系,创建CRM客户管理一体化生态解决方案。,SecPath M9000-X异常日志“Hardware failures have occurred on multiple cards. Please contact Technical Support.”