韩佳鑫,RX8800-16上单板RX-CEPC-CQ8LF起不来
1676540175,
问题描述
新上架设备RX8800-16,设备版本Version 7.1.075, Release 8261P29,两块单板RX-CEPC-CQ8LF插在0,1槽位显示状态为Fault
logbuffer中有如下报错
%Dec 12 15:49:18:867 2022 H3C DEV/4/BOARD_LOADING: Board in slot 0 is loading software images. %Dec 12 15:49:22:009 2022 H3C DEV/5/LOAD_FINISHED: Board in slot 0 has finished loading software images. %Dec 12 15:49:22:085 2022 H3C DEV/3/LOAD_FAILED: Board in slot 0 failed to load software images. %Dec 12 15:49:37:194 2022 H3C DEV/4/BOARD_LOADING: Board in slot 1 is loading software images. %Dec 12 15:49:40:337 2022 H3C DEV/5/LOAD_FINISHED: Board in slot 1 has finished loading software images.%Dec 12 15:49:40:414 2022 H3C DEV/3/LOAD_FAILED: Board in slot 1 failed to load software images.
过程分析
将单板插在其他槽位上问题依旧,查看适配关系和RX-SFC-16T支持。
解决方法
经确认,R8385P08版本开始支持此单板,升级版本后问题解决。