问题描述

现场反馈一组堆叠的R7577P02版本的S7606X的LSUM1FAB06C3内存利用率较高,超过了百分之70,

Chassis 1 Slot 8:

             Total      Used      Free    Shared   Buffers    Cached   FreeRatio

Mem:        949632    665580    284052         0         4     57628       30.4%

-/+ Buffers/Cache:    607948    341684

Swap:            0         0         0

 

Chassis 1 Slot 9:

             Total      Used      Free    Shared   Buffers    Cached   FreeRatio

Mem:        949632    671136    278496         0         4     57628       29.8%

-/+ Buffers/Cache:    613504    336128

Swap:            0         0         0


Chassis 2 Slot 8:

             Total      Used      Free    Shared   Buffers    Cached   FreeRatio

Mem:        949632    674144    275488         0         4     57632       29.5%

-/+ Buffers/Cache:    616508    333124

Swap:            0         0         0

 

Chassis 2 Slot 9:

             Total      Used      Free    Shared   Buffers    Cached   FreeRatio

Mem:        949632    674352    275280         0         4     57632       29.5%

-/+ Buffers/Cache:    616716    332916

Swap:            0         0         0

 


过程分析

网板LSUM1FAB06C内存太小只有1G,该网板空配置起来内存剩余就很小了,另外新版本由于特性增加,很多模块都有少量的占用增加,属于正常占用,加起来增加就多了,而单板内存又太小,导致单板剩余内存过少。


解决方法

网板不需要下发macarp、路由等表项,不会影响业务。建议现场继续使用,如果内存出现告警,按照下面的方法调整告警阈值。 

 memory-threshold chassis 1 slot 4 minor 80 severe 64 critical 48 normal 96 early-warning 100 secure 140